Lift and Elevator Codes and Standards in Spain
New lifts are placed on the market under Real Decreto 203/2016, which transposes the Lifts Directive 2014/33/EU (CE marking, notified bodies). Commissioning, modification, maintenance and inspection of lifts in service are governed by ITC AEM 1 'Ascensores', approved by Real Decreto 355/2024 (in force 1 July 2024; it repealed RD 57/2005 and RD 88/2013), administered by the regional (autonomous community) industry authorities, and amended by RD 164/2025 (owner notification of inspection dates, quality-system route for major modifications, transitional rule for existing lifts), RD 485/2025 (a Valencia-only moratorium that ran to 1 July 2026) and RD 770/2025 (maintenance-company staffing). Existing lifts without a CE/UE declaration must add the safety measures listed in Annex VII of the ITC, most within one year of the first periodic inspection that finds them missing (two-way car communication, load control, automatic-door protection 25-1,600 mm; levelling ±10 mm stopping / ±20 mm levelling for single-speed drives), with 3-10 year deadlines for old guide rails and counterweight guiding; an owner may ask the regional authority for exemption with an inspection-body report. Under the Horizontal Property Law (art. 10.1.b, as amended by RDL 7/2019 and Ley 4/2026), accessibility works including installing a lift are compulsory without a meeting vote when requested on behalf of a disabled resident or one over 70, within a cost cap of 12 monthly service charges after subsidies (no cap once subsidies reach 70 %); otherwise a simple majority suffices to establish a lift service (art. 17.2, Ley 10/2022).
Who regulates lifts
Ministerio de Industria y Turismo (national rule-maker); autonomous-community industry departments (competent bodies for registration and enforcement)
Periodic inspection
Accredited organismo de control (OCA, RD 2200/1995): every 2 years for lifts in industrial buildings or public-access premises; every 4 years for buildings with more than 20 dwellings or more than 4 floors served; every 6 years otherwise (ITC AEM 1 art. 11.4). Minor defects must be corrected within six months of detection (art. 11). Since RD 164/2025 the maintenance company must notify the owner of the inspection deadline and take the lift out of service on the next working day if the inspection has not been done (art. 11.6.a / 7.7). A lift stopped for more than three months needs an annual-scope UNE 58720 maintenance check before restart. Inspection content per UNE 192008-1/-2.
Installer and maintenance licensing
Yes. A maintenance company (empresa conservadora) files a declaración responsable with the regional competent body (valid nationwide) and must have at least one university-qualified technical manager and one qualified conservador; since RD 770/2025 (art. 6.9.b ITC AEM 1) these may be employed under any lawful contract form and may be the same person if qualified for both. Civil-liability insurance of at least EUR 600,000 per accident (stored, not re-checked this run). The conservador must hold a qualifying degree, vocational title, experience recognised under RD 659/2023 (wording from RD 164/2025) or an accredited personal certification.
Laws, codes and standards
- Ley 10/2022 (2022) — Act 10/2022 on urgent measures to boost building renovation under the Recovery, Transformation and Resilience PlanMandatory · Cortes Generales
- Ley 4/2026 (2026) — Act 4/2026 amending the consolidated General Law on the rights of persons with disabilities and Law 39/2006, extending accessibility rights (final provision 1 amends Horizontal Property Act art. 10.1.b)Mandatory · Cortes Generales
- Ley 49/1960 de Propiedad Horizontal, arts. 10.1.b and 17.2 (amended by RDL 7/2019, Ley 10/2022, Ley 4/2026) — Horizontal Property Act (condominium law) — compulsory accessibility works incl. lifts, and majority to establish a lift serviceMandatory · Cortes Generales
- Real Decreto-ley 7/2019 (2019) — Royal Decree-law 7/2019 on urgent housing and rental measures (amended Horizontal Property Act art. 10.1.b: lifts at the request of disabled/over-70 residents)Mandatory · Gobierno de España
- RD 164/2025 (final provision amending RD 355/2024 / ITC AEM 1) (2025) — Royal Decree 164/2025 approving the Fire Safety Regulation for industrial establishments (one final provision amends RD 355/2024 and ITC AEM 1)Mandatory · amends RD 355/2024 · Gobierno de España (Ministerio de Industria y Turismo)
- RD 1644/2008 — Royal Decree 1644/2008 of 10 October laying down the rules for the marketing and putting into service of machineryMandatory · Transposes Machinery Directive 2006/42/EC (BOE 246/2008, 11 Oct 2008; in force 29 Dec 2009; consolidated text amended by RD 494/2012 and RD 302/2026) · Government of Spain (BOE)
- RD 203/2016 (2016) — Essential safety requirements for placing lifts and safety components for lifts on the market (transposition of Directive 2014/33/EU)Mandatory · Directive 2014/33/EU · Ministerio de Industria, Energía y Turismo
- RD 355/2024 (ITC AEM 1) (2024) — Technical Complementary Instruction ITC AEM 1 'Lifts' (commissioning, modification, maintenance and inspection of lifts)Mandatory · Ministerio de Industria y Turismo
- RD 485/2025 (final provision 2: transitional provision 5 of RD 355/2024) (2025) — Royal Decree 485/2025 amending RD 874/2017 and RD 1071/2021 on shipbuilding support (its second final provision adds a temporary Valencia moratorium to RD 355/2024)Mandatory · amends RD 355/2024 · Gobierno de España (Ministerio de Industria y Turismo)
- RD 770/2025 (art. 10: ITC AEM 1 art. 6.9.b) (2025) — Royal Decree 770/2025 amending several industrial-safety regulations on the hiring arrangements for qualified professionalsMandatory · amends RD 355/2024 (and ITC MIE-AEM-2 and other ITCs) · Gobierno de España (Ministerio de Industria y Turismo)
- CTE (RD 314/2006) as amended by RD 732/2019 and RD 450/2022 — Spanish Technical Building Code — post-2018 amendmentsMandatory · Gobierno de España
- UNE 192008-1 / UNE 192008-2 — Inspection procedure for lifts (part 1: lifts under lift legislation; part 2: lifts up to 0.15 m/s under machinery legislation), incl. defect classificationReferenced by law · ITC AEM 1 Annex XII · UNE
- UNE 58720 (2020) — Preventive maintenance of liftsReferenced by law · ITC AEM 1 (preventive maintenance checks), Annex XII · UNE
- UNE-EN 115-2 (2022) — Safety of escalators and moving walks - Part 2: Rules for the improvement of safety of existing escalators and moving walksVoluntary · UNE / CEN
- UNE-EN 81-20 (2020) — Safety rules for the construction and installation of lifts — passenger and goods passenger liftsHarmonised (presumption of conformity) · RD 203/2016 (presumption of conformity); cited in ITC AEM 1 Annex XII · CEN / UNE
- UNE-EN 81-21 (2022) — New passenger and goods passenger lifts in existing buildingsReferenced by law · Cited in ITC AEM 1 Annex XII / Annex VII · CEN / UNE
- UNE-EN 81-50 (2020) — Design rules, calculations, examinations and tests of lift componentsHarmonised (presumption of conformity) · RD 203/2016; cited in ITC AEM 1 Annex XII · CEN / UNE
- UNE-EN 81-70 (2022+A1:2022) — Accessibility to lifts for persons including persons with disabilityReferenced by law · Cited in ITC AEM 1 Annex XII; two-way communication upgrade must be accessible per this standard · CEN / UNE
Lift associations and bodies
- Association of Lift Component Companies (AECAE)
- Spanish Federation of SME Lift Company Associations (FEPYMA)
- Spanish Lift Business Federation (FEEDA)
Last verified 2026-10-17. Standards are copyrighted: we list which one applies and its legal status, not its text.