Sign up free →

Lift and Elevator Codes and Standards in Kazakhstan

Kazakhstan is in the Eurasian Economic Union: new lifts and lift safety devices must conform to TR CU 011/2011 'Safety of lifts' (Customs Union Commission Decision No. 824 of 18 Oct 2011, in force 15 Feb 2013); EEC Board Decision No. 93 of 29 May 2018 lists the interstate GOST standards (GOST 33984.1-2016 = EN 81-20:2014 and others) that give a voluntary presumption of conformity. In operation, lifts fall under the Ministry for Emergency Situations' industrial-safety rules: Chapter 5 'Freight and passenger lifts' of the Rules for industrial safety when operating lifting mechanisms (order No. 359 of 30 Dec 2014, amended by MES order No. 43 of 27 Jan 2023), and lifts past their 25-year normative service life must be examined by an attested organisation before further use (MES order No. 481 of 29 Sep 2021). Escalators have their own MES rules (order No. 479 of 29 Sep 2021): registration after commissioning and periodic technical inspection at least once every 12 months. State control over lifts in apartment buildings sits with local executive bodies (akimats, housing inspection); the lift owner is the OSI/KSK. Lift work is not licensed (licensing abolished 2012-2014 per press); installation, maintenance, inspection and repair organisations need an industrial-safety attestation under Article 72 of the Law 'On Civil Protection'.

Who regulates lifts

Committee for Industrial Safety, Ministry for Emergency Situations (operating rules, attestation); local executive bodies (akimats / housing inspection) for state control of lifts in apartment buildings; Eurasian Economic Commission for product conformity (TR CU 011/2011)

Periodic inspection

Lifts: periodic technical inspection at least once a year (stated by the chair of the MES Committee for Industrial Safety, Oct 2026 press); lifts past 25-year service life need a condition examination, repeated every 1-3 years, max three times (MES order 481/2021). Escalators: periodic technical inspection at least once every 12 months (MES order 479/2021, p.153).

Installer and maintenance licensing

No licence (lift-company licensing abolished, per press); organisations installing, maintaining, diagnosing, inspecting or repairing lifts and escalators must hold an industrial-safety attestation under Article 72 of the Law 'On Civil Protection' (MES order 479/2021 p.3; MES Committee chair, 2026 press).

Laws, codes and standards

Lift associations and bodies

Last verified 2026-10-19. Standards are copyrighted: we list which one applies and its legal status, not its text.